  • Effect of Molecular Weight On Compressor Performance
    Dear All, I have extensively studying the analysis of the impact of Molecular weight changes on fixed speed and variable speed compressors Can you provide your feedback on the below simplified summary: 1) Fixed Speed Compressor, fixed compression ratio, speed and head at every flow: a) With
  • NPSH vs. Pressure | Eng-Tips
    Hi all, I am having trouble trying to distinguish the difference between NPSH and pressure I know that NPSHr is what you must have in order for the pump to not cavitate It is equal to: (static height) + (pressure within vessel) - (vapor pressure) - (pipe friction losses) For example
  • Torque spec changes from nut to bolt head? | Eng-Tips
    In a torque spec for a typical bolt, washer and nut arrangement, is the proper torque value affected whether it is applied to the bolt head as opposed to the nut? Thanks!
  • Please help clarify datum shift vs bonus tolerance | Eng-Tips
    Then the datum shift is the difference between the actual size and the virtual condition size developed by the refinement tolerance If the same hole was a tertiary, the the shift is the difference between the actual size and the virtual condition size developed through the positional tolerance rather than the refinement
  • VFD and induction motor power factor | Eng-Tips
    The difference can depend on the line voltage vs the VFD output voltage If you set the VFD to 460V motor it will output 460V even with a different line voltage (within limits of course) The change in voltage could affect the output current I've seen this mostly be a factor when the motor voltage setting is set too high
  • Internal wind pressure | Eng-Tips
    So when you get a net difference between a set internal pressure and a different exterior pressure, you get a net pressure applied to the walls of the box This is not necessarily the full internal pressure effect used in ASCE 7
  • How much does vertical load affect the lateral load capacity of piles . . .
    In general, how much does vertical load (compression or tension) affect the lateral load capacity of piles? It seems like whenever I get the geotechnical engineer to run an L-PILE analysis for me, the vertical load doesn't seem to be that consequential
  • Wind effect on heat loss gain through walls | Eng-Tips
    In cooling the difference between indoor and outdoor temperature factors in mainly on infiltration and ventilation The heat gain through walls is more about the heat from the sun beating on the wall, than it is the temperature differential between indoor air and outdoor air