  • 2 Air Admittance Valves on double sink, IPC 2009
    Hey All, My local inspector allowed me to use AAVs on my kitchen double sink, as there was no good way to hard vent it He said that a double wye with an AAV off the top was not allowed in our municipality, and that I have to have 2 AAVs I guess a 2" hard vent is ok off the top of a double
  • Replacing an Automatic Air Vent - Love Plumbing Remodel
    The AAV is equipped with a float located internally, which is utilized to open close a bleeder valve The float will not 'float' when the chamber contains air, so the bleeder valve will remain open, thereby allowing air to escape
  • Kitchen S trap to P Trap and AAV set up help.
    Hi, My sink has been plumbed with an S Trap since I remodeled In 2010, I get gurgling when dishwasher runs and sometimes sink drains slow ( speeds up if I manually open AAV ) I ordered a new AAV ( white code approved one ) and then I got researching and see it's supposed to be higher then
  • what can I do if Cheater Air Admittance Valves are not allowed?
    AAV's are prohibited in the Uniform Plumbing Code, It is not that the UPC specifically prohibits AAV's It is a default position that AAV's are not an approved product under IAPMO and therefore they are not addressed within the UPC
  • Air Admittance Valve seems to be a problem - Love Plumbing Remodel
    The issue can be solved by a similar aav valve that is used in a case of positive pressure What seems to be occuring is that the air pressure when the sink goes to drain, is pushing the valve closed which would happen in a similar situation like a check valve
  • Washing Machine + Slop Sink + AAV - Love Plumbing Remodel
    The AAV is a one way valve letting air in to prevent siphonage, which BOTH traps need and your AAV will provide The positive pressure situation occurs if the discharge is greater than the pipe can accomodate causing a pressure buildup, which will limit or prevent, the drainage and affect the sink's trap
  • Basement Bathroom Wet Vent + AAV - Love Plumbing Remodel
    DIY plumbing a basement bathroom in Michigan (IPC) and am wondering about venting Only real access to existing stack is a 3" line that carries waste from other bathrooms on other floors so I believe that is a no-no I've got a revised plan drawn out and attached I can use an AAV in my location
  • Distance to air gap drain. - Love Plumbing Remodel
    Yes for the IPC, although that requires you to get the exact slope of 1 4" per foot Slope it more, you reduce the maximum horizontal No for the UPC, as it further imposes a limit of 42" for a 1 5" trap arm If the laundry sink were to the right of your drain, you could run a horizontal trap arm from the triple sink, with an AAV within the distance limits discussed above, then around the