- Equipment Bollard in a Residential Garage - The Building Code Forum
Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
- S-1 S-2 Regarding Parking Garage - The Building Code Forum
Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
- Garage pedestrian door size | The Building Code Forum
I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
- 2024 Portal Frames | The Building Code Forum
In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
- Garage distance separation from dwelling - Section R309
Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
- Step from garage into House?? | The Building Code Forum
I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
- Garage - No Man Door | The Building Code Forum
Does a detached accessory structure, such as a garage, require a man door, or is the overhead door sufficient?
- fire separation in garages - The Building Code Forum
When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
|
|
|