- Cummins insite with a ram | Cummins Diesel Forum
Hi, i work in a truck shop and i have insite with a inline 7 for the shop, was wondering if any of you guys that might have access to insite and tired to connect to a 19+ ram with it on the private network? I just bought a 24 and would love to be able to connect to it! Thanks
- Cummins INLINE 7 or Nexiq USB Link 2 | Cummins Diesel Forum
Cummins INLINE 7 Data Link Adapter with Insite 8 3 Multi-language Software Nexiq USB Link 2 + Software Diesel Truck Interface and Software with All Installers which to choose?
- connecting to ecm using insite | Cummins Diesel Forum
does anybody know how to connect to there ecm using insite iv heard a couple rumors that with insite 8 4 you can connect to the ecm using the 3 pin backbone connector on the harness?? im gona give it a try this weekend
- Insite Data monitor problem | Cummins Diesel Forum
Everything else on insite that I use works, just not the data parameters I am running windows 7 I am using Pro version, but I will still check This is a new system and has only been used a dozen times We have 2 cummins trucks and it has worked previously on both trucks After the freeze and disconnect, the data parameters dont work on either
- Anyone tried using Cummins INSITE on the 2013+ truck
Has anyone tried yet? The ECM looks identical to the CM2350 used on every other Cummins EPA 2013 engine I'm thinking if J1939 is enabled to broadcast it might work
- Cummins Insite or Jpro - Dodge Cummins Diesel Forum
Cummins Insite and JPRO are both popular diagnostic tools for heavy-duty trucks Here are some key differences between the two: Compatibility: Cummins Insite is specifically designed for Cummins engines, while JPRO is compatible with a wide range of heavy-duty trucks, including Freightliner, International, Volvo, and more
- Vgt actuator calibration help | Cummins Diesel Forum
I just re installed my modified vgt back on the truck and the veins are moving up and down searching Apparently it needs to be recalibrated which I was told it did not Anyway I am looking for a little advice from someone who has done this I saw this can be done with a snap on scanner I am
- Early 2004 Long crank issue | Cummins Diesel Forum
Since I have an Edge Insite CTS I could monitor rail pressure while cranking and could see that it was slow to build enough pressure to fire the injectors Retorquing the feed tubes helped for a while but just put off the inevitable New injectors solved the problem If your injectors do have 370k on them they probably are past time to replace
|
|
|