  • Understanding the 75°C vs 90°C column in Ampacity Table. . .
    The columns indicate how much amperage is required to raise the temperature of that size conductor to that column's temperature under standardized conditions So a 2 0 XHHW will reach 75°C at 135A and 90°C at 150A The wire insulation is good for 90°C, so for sizing the wire, we can use the
  • High bays hanging from rigid conduit - Electrician Talk
    My AI NEC assistant tells me this is permissable Yes, the National Electrical Code (NEC) allows luminaires (light fixtures) to be supported by a chain from a rigid conduit under specific conditions
  • Ground rod horizontal in ditch - Electrician Talk
    Grounding in NEC has become a cruel joke It’s like tge stupid 25 ohm maximum rule, OR just use 2 rods Granted the Earth electrode isn’t as critical as they make it out to be, or they would just stop with saying 25 ohms or less and basically we don’t care how you get there I’m not a fan though of anything but a single point ground rod
  • Continuous Load: what is maximum current | Electrician Talk
    From the 2023 NEC Article 100 Definition: Continuous Load: A load where the maximum current is expected to continue for 3 hours or more 210 20(A) Continuous and Noncontinuous Loads "Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads
  • NEC Requirements for Generators and Standby Power Systems
    NEC Requirements for Generators and Standby Power Systems Rule 220 87, Articles 445, 700, 701, and 702
  • Branch Circuits - Electrician Talk
    Branch circuits The distinction between a branch circuit and a feeder can be a source of confusion for the Code user The first step in eliminating this confusion is to understand that the NEC defines a branch circuit as “the conductors between the branch-circuit final overcurrent device protecting the circuit and the outlets” (such as receptacles or lights) [Article 100]
  • PowerPoint Presentation
    The NEC does not define ranges, ovens or cooktops but based on manufacturers usage a range is a unit that has a cooktop and oven built together in one appliance An oven is just a single or double appliance for baking , roasting, etc A cooktop is just the burners without the oven
  • Rule of six disconnects - Electrician Talk
    Service disconnects are limited to 6 switches or sets of circuit breakers 2017 NEC 230 71 (A) Probably same for 2020 They sell 42 space main lug panels for use as sub panels with NO main breaker installed in the panel Code compliant Your situation is a Sub Panel