- Navien NPE-240S external circulating pump - Love Plumbing Remodel
To install an external circulating pump on the Navien NPE-240S, you'll need a few things First, make sure you have the pump itself, along with any necessary fittings and piping
- Navien NPE-240A and NaviCirc Installation Question
Hello, I just had my Navien NPE-240A (EDIT: It's actually an NPE-240A2) and NaviCirc installed today First time tankless user I was reviewing the manual and installation after they left, and I don't think they have the NaviCirc hooked up properly, and I want to confirm before I call them back
- Navien NPE-240A Recirculation Question - Love Plumbing Remodel
Hi all, we had a Navien NPE-240A installed in 2014, and have been happy with it We did have a weird issue with water temperature being colder than expected occasionally, but it always went away This year we switched to a new servicer who told us it had been installed wrong and was set to
- Navilink Lite NPE 240A - Love Plumbing Remodel
I have a Navien NPE 240A about 3 years old and decided I'd like to try Navilink Lite for better control Connected the Navilink Lite unit and WiFi is showing steady blue light and com lite is steady red
- Navien LP to NG conversion - Love Plumbing Remodel
Ok, so when I bought my house, I knew I'd be converting to NG within a few years Our old tank wh was leaking so we replaced it with a Navien NR-240A (LP model) tankless Our plumber told us that Navien's rep directly told him it was convertible to NG (and we unfortunately did not get this in
- Navien NCB240E Pressure problems - Love Plumbing Remodel
My Navien Combi Boiler installed Dec 2019 consistently runs at a high pressure - 27-30psi The following conditions exist: I have a 4-zone system with Tac0-570-2 valves in a 3,000 sq ft home with highly oxygenated well water; when first installed it was not set for fin radiators- that was
- Diagnosing problems with NPE 240A recirculation
Navien, taco, grundfos, and any other pump needs water to pump Some have different ways to bleed air and there are many many different methods with different mechanisms to bleed air from systems but it's basic and required
- Navien 240A not getting generating very hot water
Hello I have a Navien NPE 240A About 6 yo Propane Re-circulation pump programed to run 5AM to 10PM I clean the filters and de-scale annually I'm seeing a variation of the issues outlined above 1st Recently the hot water at the faucets began arriving slower (less instant) Takes about 5-10 seconds for expected hot water
|
|
|