  • What is a full strength penetration weld? | Eng-Tips
    Doesn't full penetration refer to a weld the full depth of the material being welded independant of strength? My interpretation is penetration is the distance your weld extends below the plate surface
  • MAX. PENETRATION, MAX. CONTACT FORCE ERROR and NEGATIVE EIGENVALUES . . .
    Hello, I'm doing a simulation in abaqus standard and i wont to know if MAX PENETRATION, MAX CONTACT FORCE ERROR and NEGATIVE EIGENVALUES is a problem or i can stay with them? If yes, how can i fix them and how they afect my results Some exemples: "***WARNING: THE SYSTEM MATRIX HAS 23
  • abaqus - solving penetration contact error between 2 surfaces
    PENETRATION ERROR TOO LARGE COMPARED TO DISPLACEMENT INCREMENT To solve I've tried the following: - lowering increments in Step to 1e-5 - I tried offsetting the one surface from the other (to try and stop penetration error?!) - changing the interaction properties definition from hard contact to linear contact, with stiffness 10,000 and set
  • Steel Beam Penetrations (Sizes and detail?) | Eng-Tips
    Fellow engineers, I am running into a problem in the field where beam penetrations through my steel beams need to occur Our detail shows that the depth of the penetration can be D 3 (D = depth of steel beam) and the length of the penetration is 3 4*D This rectangular penetration has fillet
  • pipe penetration on structural members | Eng-Tips
    Hi guys, I need to prepare pipe penetration (vertical and horizontal) details on structural members (beams, slabs, walls and staircase) Any reference that you can suggest? Is there any standard details that can be follow? E g , for beams, penetration is allowed at some distance from the
  • New opening in existing CMU wall, limitations on width
    We are creating a new opening in an existing, standard 8" CMU wall for a duct penetration The wall is load bearing My question is what is the maximum width of the opening where a lintel would not be required? Could we provide an opening 22" wide where the blocks above each had 5" of bearing
  • Blow counts for SPT Value | Eng-Tips
    Text books describe SPT testing by penetration readings for three 6" intervals and counting the blow counts for the last 12 inches i e ignoring the reading for the first 6" Some drillers and software have readings for four 6" penetrations, a total of 24 inches E g blow counts of
  • Contact problem - negative or zero pivot | Eng-Tips
    Initial penetration is likely to cause convergence issues because it makes the determination of initial contact stiffness problematic However, it does not cause a zero- or negative-pivot error, this is mathematically impossible