- Water heater gas valve replacement: shank length
Hi Experts, I need to replace gas valve on my water heater It is a Robsertshaw R110RTSP on a Rheem Guardian 22V50F1 heater The shank length on this valve is 2-3 8" I wish to try a replacement gas valve from HD or Lowes which have smaller shank lengths This is just for ease of return if the
- 40 gallon Electric water heater wire and breaker sizing question
I bought a house that the copper was stolen including the water heater I plan on installing a cheap 40 gal Rheem 6year I have to run wiring because that is also gone I am confused about the wiring and breaker One feature of the heater is that it has Dual 4500 watt heating elements for
- Routing Supply Lines for Heat Pump Water Heater- Flex vs Hard vs
I am replacing a water heater with top side supply connections with a Rheem heat pump water heater that has side mount connections The Rheem design puts the cold water supply inlet right at floor level The model I have has an auto shutoff valve which goes on the cold nipple and results in the
- Rheem Gladiator Water Heater - Love Plumbing Remodel
This morning, the water heater decided to start beeping and the red indicator says "Service needed" Havn't had a lick of trouble with this unit since I installed it The light is blinking 4 flashes pause, 4 flashes, pause, etc Manual says: 1 Disconnection of wire(s) to upper or lower
- The dreaded Rheem flammable vapour sensor error
According to Rheem, the FVS can literally be set off by dust and humidity, and they won't replace it under warranty She lives in an old house with a damp and dusty basement that gets a bit of water during heavy rain, but this sensor was never wet or exposed to any kind of flammable vapour
- Choosing model series from Rheem and Bradford White
Rheem and Ruud are the same unit and same company The "Thermocouple" is no longer a thermocouple but is a "Thermopile" that both provides flame sensing but generates the millivolt power to operate the control so you do have to hold it in the pilot lighting position longer until it heats up and starts generating the voltage required
- Rheem Tankless Water Heater Error Code 12 - Love Plumbing Remodel
I'm asking this learned group because Rheem doesn't have a "contracting plumber" in Grand Junction and most of the plumbers here are not familiar with tankless units I've done all the diagnostic checks suggested by Rheem and they all check out; voltage to the white and blue molex, flame rod status, etc
- AO Smith, Reem or Stiebel Eltron Which hybrid water heater brand is . . .
Additionally, I have been attempting to research three brands consisting of AO Smith, Rheem, and Stiebel Eltron; but the information that I've gathered has been rather conflicting
|
|
|