- Romex | Information by Electrical Professionals for Electrical . . .
In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex Although IF the building can be a type 3,4 or 5 building you can in fact install Romex Can someone interpret this code 334 for me?
- Romex in conduit attached to an enclosure (indoors), fastening . . .
When using conduit to protect Romex before it enters an enclosure - for example, coming up out of the crawlspace, up an un-finished wall to a disconnect - what fastening requirements are recommended and or required ? (The conduit would run from the floor to the box)
- Romex wiring in garage | Information by Electrical Professionals for . . .
I'm buying a house and there is romex wiring run through the garage The installation was approved by the township in 1987 when it was installed Current standards requireany type of non-metallic wiring, Romex included, to be protected (within conduit) It's 28 years old and I want the seller
- Romex outdoor application | Information by Electrical Professionals for . . .
Can indoor romex be used in an outdoor structure if the ceiling is enclosed Everything else on the structure is open it will basically be cedar covering the rafter bays
- Garage romex protection | Information by Electrical Professionals for . . .
Where in the code is it required, (or not) the need to protect NM cable run in a garage, horizontally through bored holes in stud runs that are exposed (not covered with drywall? Items can be hung from the cable for example, pulling the cable from its connectors So is drywall or similar
- Megging romex. What values am I looking for? | Information by . . .
I recently purchased a new fluke 1507 I have a job for a residence that had a small fire I have been requested to megger the wiring to verify its integrity Can anyone give me any direction as to what voltage I should run my tests at and what values I am looking for? Do the different types of
- Romex in conduit | Information by Electrical Professionals for . . .
I was wondering if there is any restriction to installing romex wire in conduit? The code states you can do it for physical protection So is there any ruling against running it in conduit when there is no need for protection? Thank you for your help
- Spray Foam Romex | Information by Electrical Professionals for . . .
So hoping I can get a little help advice here Had my attic ceiling spray foam insulation done All along the perimeter it becomes pretty tights I had a bunch romex run along the rafters which they completely covered with the spray foam I mean like 4+ inches of spray foam encapsulating the
|
|
|