- Vermont casting dauntless | Hearth. com Forums Home
I just bought this stove, without a cat,this year as I moved into a new house, and replaced the old stove onto the existing chimney system It is a wall exit setup with 2 90s and is probably a hair too short to meet normal standards However, when the stove is running well, draft is not an issue
- heating entire house from basement | Hearth. com Forums Home
we are looking at buying a house that has a stone fireplace in the living room and a place in the basement to connect a woodstove, the house is 1456 sq ft on one floor and the basement is same sq footage and completely open was wondering if placing a woodstove in the basement wood supply enough heat to the main living floor to heat without
- No power to circulator pump | Hearth. com Forums Home
So if you tie the burner pump together, the pump will stop every time the boiler gets up to temp If the 8148 aquatstat is faulty, I would replace it $130 on Supply House website But I would first make very sure it is faulty Part of a typical setup also is that there is a zone valve between the thermostat, and the aquatstat
- House layout | Hearth. com Forums Home
House size is about 1225 sq ft , and not well insulated (MAYBE r-11 in the attic), and I lose heat somewhat quickly I'll be working on the insulation The stove we have now is about 2 4 cu ft , and does a good job keeping the house warm, so I'm thinking a similar sized stove would fit the bill
- Rainey’s home (homestead rescue) burns to the ground
That set up looks like what some anthracite burners make to keep as much heat as possible inside of the house , also many anthracite stoves are called * base burner* cause having long flue path under the firepot to keep the gases heat as long as possible inside of the house
- my stove pipe leaks smoke into my house - Hearth. com Forums
Chimney needing cleaning often, blackened glass, smoke leaking at seam; first thoughts are stove being run too low, wet wood, poor draft or a combination of these
- Are there any wood burning stoves designed to be used while the doors . . .
The modern stoves have a beautiful view with the door closed to, the glass stays nice and clean if it's operated properly I have a fireplace and a stove, well 2 stoves I use the stove to heat the house and the fireplace on spring and fall days, when it's just a little chilly I love having both and highly recommend it!
- How far can I run copper tubing for propane? - Hearth. com Forums
around here there is typically a regulator screwed into the tank, a 3 8" line going to the house, and another pressure regulator at the house going to bigger lines inside the house I don't know why you would have 5 8" going from the tank to the house, but if you do then you may have different pressures than are used here
|
|
|