Fasteners on curved surface | Eng-Tips Working on a sheet metal assembly where I need to put some screws through the side wall of a circular cylinder But SolidWorks refuses to properly mate the screws to the holes in the assembly Can't add any relations to get the screws properly positioned relative to the holes, and Smart
amp readings? | Eng-Tips here's the story, the plumbers in the building maint department say there is a clog in the 8inch pipe down the line from the discharge well when the pump runs,after about 30mins, it heats up and the amp reading are 6 4amps on each phase the nameplate on the motor is 9 5amps on a 480volt connection question, if there was a clog on the pipe wouldn't the amps be higher than 9 5amp and than
Pipeline design for pigging - general advise | Eng-Tips A few years ago the smallest smart pig you could find was 6-inch, I hadn't heard that anyone was marketing a 2 or 3-inch smart pig these days--the industry tends to think of 2 and 3-inch pipe as disposable
Instantiating Document Templates | Eng-Tips I've noticed recently when instantiating document templates, sometimes it saves the files as CATProduct123 CATProduct or CATPart123 CATPart, and not save the file to the instance part name in the tree I've also noticed it somemtimes pulls a copy of the document template highest product level
Primary Value of Smart Dimension dimmed out | Eng-Tips Hello, Newbe to SolidWorks 2010 I am designing a part with a slot in it The slot is supposed to be 30mm wide and I erroneously made it 40mm wide Using the Smart Dimension tool I want to change the dimension However the Dimension panel shows the Primary Value dimmed out and I cannot
antenna delta match impedance | Eng-Tips Anyone know where to find the equations for dimensions of a delta-match for a desired impedance? I find dimensions for 600ohm delta match everywhere A 300ohm should tap a little closer to the middle of a half-wave dipole I can't seem to find equations for this anywhere online I know that
Montemayor | Eng-Tips I was just out of bed when Rita showed up on the North Coast of Cuba, but I did the smart thing: I stayed home and got better just watching all the ruckus and hulaballo raised by the TV As you know by now, the greatest majority of deaths are all directly due to the mass hysteria and evacuations directed by the media
Control valve - CV at 100% open | Eng-Tips Hello people, How can i obtain the the CV value of a control valve at 100% open, knowing the CV value at 80% open for example? Thanks "We don't believe things because they are true, things are true because we believe them " "Small people talk about others, average people talk about things, smart people talk about ideas and legends never talk "
Tolerancing grayed out on drawing when adding modifying hole . . . I have a part with a hole wizard hole On it's respective drawing, I'm trying to add a tolerance to the hole I click on the "Hole Callout" dimension and under the Tolerance Precision selections, None, and 125(document) dropdowns Both are are grayed out, and not drop down-able I've also