Garage pedestrian door size | The Building Code Forum I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
New construction attached garage slab - to bear or not bear on frost . . . The diagram shows a section view of a draft of my new home Cars will enter the two car garage towards you, over a 4' frost wall There are two sections of 4' frost wall that extend on each end of the full height foundation wall on the left, and there are 4' frost walls at the rear of the
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
HVAC in a garage - The Building Code Forum Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the
Can a HVAC be located in garage to feed house only? Ran across something yesterday Noticed they had a HVAC direct vent furnace in garage to feed a portion of a house No takeoffs for garage from this system, however was curious if it can be mounted in a garage without being boxed in? My initaial thoughts are no because what if a car was running
Step from garage into House?? | The Building Code Forum I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?