companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

GARAGE CLAUDE MATHIEU DEBOSS PEINT

BEAUCEVILLE-Canada

Company Name:
Corporate Name:
GARAGE CLAUDE MATHIEU DEBOSS PEINT
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 779 Rte Fraser,BEAUCEVILLE,QC,Canada 
ZIP Code:
Postal Code:
G5X 
Telephone Number: 4187742935 
Fax Number:  
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
101750 
USA SIC Description:
GARAGES AUTO REPAIRING 
Number of Employees:
 
Sales Amount:
$500,000 to $1 million 
Credit History:
Credit Report:
Very Good 
Contact Person:
 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
GARAGE DONALD VEILLEUX
GARAGE DONALD VEILLEUX
GARAGE CLAUDE MATHIEU
Next company profile:
GARAGE CENTRE DU CAMION BEAUCEVILLE
GARAGE CAMIONS GILBERT INC
GARAGE C ENR










Company News:
  • Minimum Floor Slope for Drainage - The Building Code Forum
    Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
  • Commercial Repair Garages - The Building Code Forum
    I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
  • 2024 Portal Frames | The Building Code Forum
    In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
  • Vehicle storage | The Building Code Forum
    The aggregate quantity of fuel stored in a parking garage will exceed the quantities per a control area for determining Group H, and every car has a fuel tank greater than 5 gallons, so I don’t see how fuel quantity would be a factor—I think the requirements for parking garages takes those specific hazards into consideration
  • Step from garage into House?? | The Building Code Forum
    I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
  • Exit discharge through open, but covered, parking lot
    The key is that the open parking garage is well ventilated naturally, and as a result, the products of combustion dissipate rapidly and do not contribute to the spread of fire 1028 3 Exit discharge components
  • Repair Garage Ventilation - The Building Code Forum
    What section in the 2009 IMC allows for CO detection to be the sole method to activate the required ventilation system in a 12,000 sf repair garage? Does 404 1 apply? This is not a parking garage, it is a repair garage Is the system only required to run when CO detectors are activated? What
  • Repair Garage Ventilation - The Building Code Forum
    Re: Repair Garage Ventilation No " 401 2 Ventilation required Every occupied space shall be ventilated by natural means in accordance with Section 402 or by mechanical means in accordance with Section 403 " You go to table 403 3 only if you choose not to do Section 402 natural ventilation The bigger question is, can a natural ventilation system be made code compliant? If by "natural
  • Elevation of ignition source - The Building Code Forum
    The requirement for the 18" elevation of an ignition source in a private garage applies to any appliance capable of generating a spark, flame or glow due to heat We commonly apply this standard to only gas appliances but an electric spark from a motor or switch offers the same concern With
  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer