copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
Garage pedestrian door size | The Building Code Forum I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
NC Garage Legal Finish Requirement | The Building Code Forum The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
S-1 Motor Vehicle Storage VERSUS S-2 Enclosed Parking Garage Is the following facility an S-1 Storage or S-2 Parking Garage? 7,000 SF metal building - fully enclosed with garage doors and walk doors for access - for parking church vans (all smaller than commercial vehicles) in order to keep them safe when not in use
Garage Open Air Calculations - The Building Code Forum I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
Egress Door From Garage | The Building Code Forum My attached garage has a man door, and my detached garage has a man door On the other hand, under the IBC an overhead garage door is allowed to be used as a required exit door for occupant loads of 10 or fewer (or maybe it's under 10 -- I don't remember) So if the IBC allows a garage door as an exit door, should the IRC be different?
Can a HVAC be located in garage to feed house only? Ran across something yesterday Noticed they had a HVAC direct vent furnace in garage to feed a portion of a house No takeoffs for garage from this system, however was curious if it can be mounted in a garage without being boxed in? My initaial thoughts are no because what if a car was running
R302. 5 R302. 6 (Dwelling Unit Garage Fire Separation) And Electrical . . . 2024 IRC R302 5 3 says "Penetrations through the separation required in Section R302 6 shall be protected as required by Section R302 11, Item 4," while 2024 IRC Table R302 6 requires separation on a wall between the dwelling unit and the garage of "Not less than 1 2-inch gypsum board or
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
Open Parking Garage, Natural Ventilation, IBC 2018 406 5 2 Openings For natural ventilation purposes, the exterior side of the structure shall have uniformly distributed openings on two or more sides The area of such openings in exterior walls on a tier shall be not less than 20 percent of the total perimeter wall area of each tier The