Garage pedestrian door size | The Building Code Forum I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
NC Garage Legal Finish Requirement | The Building Code Forum The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
Garage Open Air Calculations - The Building Code Forum I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
When is a portal frame not needed for a garage door? Typically when I draw a garage I just default to the portal frame since they're usually narrow in my area; not much meat on either side of the door I have one coming up that is, for once, not It's a 30x30, 11' ceilings, with a 14' door centered on the gable end I'm having a hard time pointing
Stepped foundation wall to reduce rise from garage to house - joist on . . . The house was designed with 8′ foundation walls, and had a rise from the garage floor to the subfloor of 17-1 2″: 4″ for vapors + 1-1 2″ sill+ 11-1 4″ joist + 3 4″ sublfoor For multiple reasons (steps, topography, fill and grading) I would like to lower the living area and entry to have only one step up from the garage
16 Garage Door Headers - The Building Code Forum Re: 16' Garage Door Headers conarb said: It's not that simple, almost all garage door headers require portal design, and usually narrow portals integrated with the header, this always requires engineering, listen to your uncle In areas with significant lateral loads from sesmic or wind, yes In areas without such loads, it's not such an issue
Drywall, 1 2 or 5 8 on garage separation? - The Building Code Forum I have been under the impression the typical fire separation wall in residential construction, single family was 5 8 "firecode" on the garage side As a matter of fact, to comply to a resale inspection, I had to rock this certain "illegal" laundry room in a garage, overlaying the existing 1 2"