S-1 S-2 Regarding Parking Garage - The Building Code Forum The garage in question is not accessory to the Business occupancy and will be used to store the business Owner's large RV Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy
Step from garage into House?? - The Building Code Forum --1994, Section 411 2 8: "Connection of an automobile parking garage with any room in which there is afuel-fired appliance shall be by means of a door way with a raised sill at least 8 inches above the garage floor or through a vestibule providing two door separation " So the southern code was concerned with ignition of gasses
2024 Portal Frames - The Building Code Forum By code, one could use a portal frame to support a 20’ wide garage door, but not this case with a much smaller opening If the three windows were replaced with a triple, mulled unit, I would assume it would be acceptable, which seems somewhat ridiculous Portal frames are not just used for garage doors (except for the PFG)
Repair Garage Ventilation - The Building Code Forum What section in the 2009 IMC allows for CO detection to be the sole method to activate the required ventilation system in a 12,000 sf repair garage? Does 404 1 apply? This is not a parking garage, it is a repair garage Is the system only required to run when CO detectors are activated? What standard determines the ppm level that activates the
Ventilation System For Lube Pit | The Building Code Forum Floor areas in major repair garage up to 18" AFF are considered classified, unless 4 ACH mechanical ventilation is provided and the vents for exhaust and makeup air are within 12" of the floor Ventilation must be continuous during occupied hours [F] 502 15 Repair garages
Vehicle storage - The Building Code Forum 1 Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 10,000 square feet (929 m2) 2 Buildings not more than one story above grade plane, with a fire area containing a repair garage exceeding 12,000 square feet (1115 m2) 3
Vehicle Repair and Sand Oil Separators - The Building Code Forum Garage [ RE: Section 301 3, `12 IPC ] The number of Floor Drains and or Trench Drains will depend on how much floor area will be used to service, repair or wash vehicles [ RE: Section 1003 2, 1003 4 1 1003 4 2, `12 IPC ] Someone will have to design your total amount of areas that will be considered for use, select an approved number of
HVAC in a garage - The Building Code Forum The leakage around a garage door and the cubic volume of a double car garage should provide an adquate supply of combustion air to any "B" vented unit We have encouraged CO detectors in homes with attached garages for years especially if a HVAC unit is installed in the garage
Vehicle Repair Facility - Use Group Occupancy? 5248 s f motor vehicle repair maintenance garage a maintenance bay: 2569 s f b storage room: 852 s f (incidental to maintenance bays?) c employee accomodations (employee break room, toilet shower locker rooms): 1827 sf (break room = 721 sf) 1 applicable building code: 2011 ohio building code 2 primary occupancy: s-1 3 construction type
Coiling Overhead Door as Egress Door - The Building Code Forum I'm pondering when I can use an overhead door as an exit The CBC is pretty clear (1010 1 2) that a swinging door isn't required in a garage factory storage use if the space is small (less than 10 occ ) Think storage unit But there is also an exception for power-operated doors complying with 1010 1 4 2