copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
Garage pedestrian door size | The Building Code Forum I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
Drywall, 1 2 or 5 8 on garage separation? - The Building Code Forum I have been under the impression the typical fire separation wall in residential construction, single family was 5 8 "firecode" on the garage side As a matter of fact, to comply to a resale inspection, I had to rock this certain "illegal" laundry room in a garage, overlaying the existing 1 2"
Step from garage into House?? | The Building Code Forum I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
NC Garage Legal Finish Requirement | The Building Code Forum The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
Car Ramp maximum slope - The Building Code Forum Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406 4 2 through 406 4 8 and shall be classified as either an open parking garage or an enclosed parking garage