companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

GARAGE LEO GROULX ATELIER DEBOSSE

MONTEBELLO-Canada

Company Name:
Corporate Name:
GARAGE LEO GROULX ATELIER DEBOSSE
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 961 Rue Notre-Dame,MONTEBELLO,QC,Canada 
ZIP Code:
Postal Code:
J0V 
Telephone Number: 8194236221 
Fax Number:  
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
26580 
USA SIC Description:
AUTO BODY REPAIR & PAINT 
Number of Employees:
 
Sales Amount:
 
Credit History:
Credit Report:
 
Contact Person:
 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
GAUTHIER, FRANCOIS
GARAGE MUNICIPALE MONTE BELLO
GARAGE LEO GROULX ATELIER
Next company profile:
GARAGE JEAN-CLAUDE MAJOR INC
GARAGE JEAN CLAUDE MAJOR INC
FLEURISTE LA ROSE DOR










Company News:
  • Residential service pit - The Building Code Forum
    How does a hole in the garage floor comply with this::: 406 3 3 Garage Floor Surfaces Garage floor surfaces shall be of approved noncombustible material The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway Click to expand
  • Ventilation System For Lube Pit - The Building Code Forum
    Floor areas in major repair garage up to 18" AFF are considered classified, unless 4 ACH mechanical ventilation is provided and the vents for exhaust and makeup air are within 12" of the floor Ventilation must be continuous during occupied hours [F] 502 15 Repair garages Where Class I liquids or LP-gas are stored or used within a building having a basement or pit wherein flammable vapors
  • Garage distance separation from dwelling - Section R309
    Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
  • Car Ramp maximum slope - The Building Code Forum
    Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406 4 2 through 406 4 8 and shall be classified as either an open parking garage or an enclosed parking garage
  • Vehicle impact bollards? | Page 2 | The Building Code Forum
    I have a garage that has both HVAC unit and water heater (both electric) in a room at the end of the garage, in direct path of a vehicle The contractor is calling it a utility room I have told him that vehicle bollards are required The contractor is trying to tell me that the 2x4 studded wall is an approved barrier the code book states:
  • Branch Circuit to Detached Garage - The Building Code Forum
    An electrical service disconnect is located in or on the main structure One of the panelboard has a 20A GFCI breaker that is labeled "garage " The garage is detached and the circuit described is fed via conduit from the panelboard The conduit enters the garage from the outside where the
  • Commercial Repair Garages - The Building Code Forum
    I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
  • Landing required? | The Building Code Forum
    I am inspecting what looks like a mother-in-law apartment being built above an attached garage This was an existing empty space above the garage They don't want a landing on top of the stairway that goes to this space The stairway is being built in the garage but will have a wall built
  • Egress through a garage. | The Building Code Forum
    A detached garage is not going to require egress in the same manner as a habitable space How do you egress out of a garage itself?
  • Minimum Floor Slope for Drainage - The Building Code Forum
    Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer