What is a garage? | The Building Code Forum My local code enforcement official here in Maine said that I am allowed to build a structure if it is a one-story garage The thing is, I can't find a definition of what a garage is either in the local code, state law, or the IRC (2015 is applicable for my town) For the sake of avoiding asking
Elevation of ignition source - The Building Code Forum The requirement for the 18" elevation of an ignition source in a private garage applies to any appliance capable of generating a spark, flame or glow due to heat We commonly apply this standard to only gas appliances but an electric spark from a motor or switch offers the same concern With
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 After listening to both sides of the discussion, my opinion is that in the case of detached garages, R309 trumps R302 R302 is a general requirement, while R309 is a specific requirement intended for garages and carports To interpret it otherwise leads to scenarios that do not make sense
Garage fire separation and pull down ladders - The Building Code Forum Re: Garage fire separation and pull down ladders Please comment on this related issue: I have SFD plans with the attic access in the garage (for attic mounted mechanical equipment that serves the entire house) The mechanical equipment is not above the garage, but it's centrally located in the main attic
Garage Landing Door Question. . . | The Building Code Forum The energy code usually requires an exterior grade door between the garage and the house Depending on the code, it may also need to be self-closing to prevent carbon monoxide from entering the home
Garage Ceiling Receptacles | The Building Code Forum Regarding the Garage ceiling receptacles in an attached Garage (to a SFR SFD), are they required to be GFCI rated (RE: 2006 IRC, Section E3802 2, Exception # 1)? QUESTION # 1: Are they considered "readily accessible" if you have to use something to access them ( i e ladder, chair, pogo stick in action, other)? Your thoughts, and Thanks !
Basement garage fireproofing - The Building Code Forum Builder frames in a garage door opening without notifying the AHJ of the change Rough-in inspection notes: That a seperation wall and ceiling will need to be installed, with a steel door including closer and a GFCI will need to be installed Heat supply to the basement would need to be terminated
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Plans Approver said: Over and out I read the commentary and it's pure rationalization The ICC imagines that fires start in garages, so they come up with rules, and then come up with reasons after the fact The statistics don't bear out the rule
Understanding Fire Area - The Building Code Forum Isn't that the same as the SF of the floor? Specific example: In an open parking garage, if each level is separated by a 2 hour rated floor assembly, then each level is a "fire area", and the aggregate will the total SF of those fire areas, which is basically the total SF of the building