copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
Elevation of ignition source - The Building Code Forum The requirement for the 18" elevation of an ignition source in a private garage applies to any appliance capable of generating a spark, flame or glow due to heat We commonly apply this standard to only gas appliances but an electric spark from a motor or switch offers the same concern With
Commercial Repair Garages - The Building Code Forum I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
Landing required? | The Building Code Forum I am inspecting what looks like a mother-in-law apartment being built above an attached garage This was an existing empty space above the garage They don't want a landing on top of the stairway that goes to this space The stairway is being built in the garage but will have a wall built
Private Garages - The Building Code Forum Is a private garage also a parking garage I can see this answer going both ways, with out the aid of definitions Or is a parking garage the same as an open garage only with walls If so, then a parking garage and private garage are the same I have tried to treat them as 3 distinct types of buildings, private garage, parking garage, open garage
Garage HVAC Questions - The Building Code Forum The venting system for the garage consists of the 3 vents in the lower left (next to the blue filtration canister) I believe that would be the intake for the garage venting system and the gable vent on the garage wall would be the exhaust
R-2 Building with S-2 Tuck Under parking - NFPA 13 or 13R? Hi, We have a similar situation and questions here, we have an open S-2 parking garage below, and 4 stories of R-2 apartments above We’re proposing a 3-hour horizontal separation between the garage and the apartments The contractor is asking if we could use a 13R sprinkler system in the residential apartments
Car Ramp maximum slope - The Building Code Forum Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406 4 2 through 406 4 8 and shall be classified as either an open parking garage or an enclosed parking garage
fire separation in garages - The Building Code Forum When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited