companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

GARAGE VALERIO CATTELAN

LAVAL-Canada

Company Name:
Corporate Name:
GARAGE VALERIO CATTELAN
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 7225 Boul Arthur-Sauve,LAVAL,QC,Canada 
ZIP Code:
Postal Code:
H7R3X8 
Telephone Number: 4506276084 
Fax Number:  
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
753801 
USA SIC Description:
Automobile Repairing & Service 
Number of Employees:
1 to 4 
Sales Amount:
Less than $500,000 
Credit History:
Credit Report:
Very Good 
Contact Person:
Valerio Cattelan 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
GARAGE VALLIER MOREAULT INC
GARAGE VALLIER MOREAULT INC
GARAGE VALERIO CATTELAN
Next company profile:
GARAGE VAILLANCOURT
GARAGE VAILLANCOURT DEBOSS PEINT
GARAGE TOROS










Company News:
  • Minimum Floor Slope for Drainage - The Building Code Forum
    The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC):
  • S-1 S-2 Regarding Parking Garage - The Building Code Forum
    The garage in question is not accessory to the Business occupancy and will be used to store the business Owner's large RV Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
  • Can a HVAC be located in garage to feed house only?
    Ducts in a private garage that penetrate a wall or ceiling that separates a dwelling from a private garage shall be continuous, shall be constructed of sheet steel having a thickness of not less than 0 0187 inch (0 4712 mm) (No 26 gage) and shall not have openings into the garage
  • 2024 Portal Frames - The Building Code Forum
    By code, one could use a portal frame to support a 20’ wide garage door, but not this case with a much smaller opening If the three windows were replaced with a triple, mulled unit, I would assume it would be acceptable, which seems somewhat ridiculous Portal frames are not just used for garage doors (except for the PFG)
  • Garage Open Air Calculations | The Building Code Forum
    Only if a garage does not meet the requirements for an "open" parking garage in IBC 406 3 does mechanical ventilation in compliance with the IMC come into play The only time percentage of floor area or distance from an opening is a factor is the area and height increasses of 403 6
  • Step from garage into House?? - The Building Code Forum
    --1994, Section 411 2 8: "Connection of an automobile parking garage with any room in which there is afuel-fired appliance shall be by means of a door way with a raised sill at least 8 inches above the garage floor or through a vestibule providing two door separation " So the southern code was concerned with ignition of gasses
  • Egress through a garage. - The Building Code Forum
    Individual wants to build a free standing garage which is accessory to the main dwelling A part of the garage is a game room In this game room there will be an emergency escape window However to egress this game room you would have to travel through the garage 311 1 is clear egress through the garage is prohibited
  • Vehicle storage - The Building Code Forum
    1 Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 10,000 square feet (929 m2) 2 Buildings not more than one story above grade plane, with a fire area containing a repair garage exceeding 12,000 square feet (1115 m2) 3
  • 16 Garage Door Headers - The Building Code Forum
    Re: 16' Garage Door Headers The garage and other window and door openings are prescriptive see FIGURE R602 10 6 2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING A minimum 3" X 11 25" net header size is required for opening from 6ft to a maximum 18 ft That would take care of the wind and seismic shear loads Correct?




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer