companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

GARAGE YVAN BERNIER ENR

PORT-CARTIER-Canada

Company Name:
Corporate Name:
GARAGE YVAN BERNIER ENR
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 37 138 Rte,PORT-CARTIER,QC,Canada 
ZIP Code:
Postal Code:
G5B2J2 
Telephone Number: 4187666331 
Fax Number: 4187666347 
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
753801 
USA SIC Description:
Automobile Repairing & Service 
Number of Employees:
1 to 4 
Sales Amount:
Less than $500,000 
Credit History:
Credit Report:
Very Good 
Contact Person:
Gemma Larue 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
GAUDREAULT & POUDRIER
GARDERIE SCOLAIRE
GARDERIE MERE DYOUVILLE
Next company profile:
GARAGE YVAN BERNIER ENR
GARAGE STATION SERVICE BEAULIEU ENR
GARAGE RELAIS










Company News:
  • S-1 S-2 Regarding Parking Garage - The Building Code Forum
    Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
  • Garage pedestrian door size | The Building Code Forum
    I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
  • 16 Garage Door Headers - The Building Code Forum
    Re: 16' Garage Door Headers conarb said: It's not that simple, almost all garage door headers require portal design, and usually narrow portals integrated with the header, this always requires engineering, listen to your uncle In areas with significant lateral loads from sesmic or wind, yes In areas without such loads, it's not such an issue
  • 2024 Portal Frames | The Building Code Forum
    In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
  • Garage - No Man Door | The Building Code Forum
    Does a detached accessory structure, such as a garage, require a man door, or is the overhead door sufficient?
  • Garage Open Air Calculations - The Building Code Forum
    I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
  • HVAC in a garage - The Building Code Forum
    Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the
  • Minimum Floor Slope for Drainage - The Building Code Forum
    Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
  • Car Ramp maximum slope - The Building Code Forum
    Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406 4 2 through 406 4 8 and shall be classified as either an open parking garage or an enclosed parking garage




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer