S-1 S-2 Regarding Parking Garage - The Building Code Forum The garage in question is not accessory to the Business occupancy and will be used to store the business Owner's large RV Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy
HVAC in a garage - The Building Code Forum The leakage around a garage door and the cubic volume of a double car garage should provide an adquate supply of combustion air to any "B" vented unit We have encouraged CO detectors in homes with attached garages for years especially if a HVAC unit is installed in the garage
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 R309 2 is less restrictive and should be considered an exception to R302 1 Table R302 1 At 3' or less R309 2 allows 1 2" gyp on the interior of the exterior walls and permits a solid door or etc
Path of egress not thru garage needed for non-living space above . . . Width of existing garage Only 12’ wide (or a little less) Small (8’10” wide) garage door (pull up) leading to the garage (27’ deep), and then a fire-rated door to the laundry room (16’ deep), and then an exterior door to the backyard The Electrical service connection is on the exterior left side of the garage opening
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
Garage - No Man Door | The Building Code Forum That’s about 10’x20’, the size of a single parking space inside a garage in a typical residential zoning code 2 cars x 3 rows is approx 40’ deep x 30’ wide, 1200 SF, which is 6 occupants A garage of 2000 SF in area would qualify as “10 occupants or less”, at which point an egress door is not required to be swinging
NC Garage Legal Finish Requirement | The Building Code Forum The garage and or carport shall be separated as required by Table R302 6 Openings in garage walls shall comply with Section R302 5 Attachment of gypsum board shall comply with Table R702 3 5 The wall separation provisions of TableR302 6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall
Step from garage into House?? - The Building Code Forum --1994, Section 411 2 8: "Connection of an automobile parking garage with any room in which there is afuel-fired appliance shall be by means of a door way with a raised sill at least 8 inches above the garage floor or through a vestibule providing two door separation " So the southern code was concerned with ignition of gasses
Egress through a garage. - The Building Code Forum Individual wants to build a free standing garage which is accessory to the main dwelling A part of the garage is a game room In this game room there will be an emergency escape window However to egress this game room you would have to travel through the garage 311 1 is clear egress through the garage is prohibited
Garage Open Air Calculations | The Building Code Forum Only if a garage does not meet the requirements for an "open" parking garage in IBC 406 3 does mechanical ventilation in compliance with the IMC come into play The only time percentage of floor area or distance from an opening is a factor is the area and height increasses of 403 6