copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
Egress Capacity Calculator - 2024 IBC Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020 3, and Section 1010 1 1 for doors
Shaft vs. Chase - The Building Code Forum The term "chase" isn't defined in the IBC and the term "chases" is only mentioned 3 times (408 5 2, 2104 1 4, and 3412 6 3 (2012 IBC)) I find UL listings for both chases and shafts and I hear chase used in the field more than shaft So are the two terms speaking of the same thing (if not then
Fire Separation Distance Between New and Existing Building with Windows From the 2021 IBC Commentary: The Commentary says: Fire separation distance is the distance from the exterior wall of the building to one of the three following locations, measured perpendicular to the exterior wall face: an interior lot line [see Commentary Figure 202 (19)]; the centerline of a street or public way [see
Area Calculation Clarification - The Building Code Forum I have a somewhat basic (dumb?) question about area calculations - Reading through the 2009 IBC it defines building area as: 502 1AREA, BUILDING The area included within surrounding exterior walls (or exterior walls and fire walls) exclusive of vent shafts and courts Areas of the building
1, single user, unisex toilet room in coffee shop, per 2021 IBC The IBC Commentary language for exception #5 confirms this There is also the exception under the calculations portion , 2902 1 1, reading "Distribution of the sexes is not required where single-user water closets and bathing room fixtures are provided in accordance with Section 2902 1 2 "
Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and . . . Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted It outlines the scope, purpose, and administrative processes that ensure due process while safeguarding public safety, health, and welfare
Occupancy Classification for Townhouse: R-2 or R-3? R-2: "Residential occupancies containing more than two dwelling units" If each townhouse is a seperate structure, than it only contains one dwelling unit That makes it R-3, yes?
Stair Width and Handrails - The Building Code Forum Our Building Division has come to understand the required width as being the clear space measured between the handrails, based upon the language in the 2018 IBC for stairs and ramps