Running MC in Conduit? - Electrician Talk While you can secure MC with cable ties, you would need a "listed" connector at the box Someone posted to use an EMT to flex coupling: This is not code compliant The individual conductors, in MC, are not approved for use in other raceways without being in the MC jacket
NEC says MC EMT can be unstrapped when run through. . . None seem to agree with me, that MC EMT can be run, unstrapped I initially thought NM Romex was the same, but it looks like the only instance strapping isn't required is when it's run through bored holes Here is what I've found in the 2020 NEC Handbook Red blue colored text is what I'm focusing on MC
MC Cable the Fire Stop Wall - Electrician Talk I have a client that needs a new cable run through a fire stop wall The plan is to use MC cable for the cable run, but I don't how to penetrate the fire stop wall with the MC Does anyone know the proper way to accomplish this??
Changeover MC to EMT - Electrician Talk Where the wiring method is conduit, tubing, Type AC cable, Type MC cable, Type MI cable, nonmetallic-sheathed cable, or other cables, a box or conduit body shall be installed at each conductor splice point, outlet point, switch point, junction point, termination point, or pull point, unless otherwise permitted in 300 15 (A) through (L) (F
MC cable to PVC pipe - Electrician Talk Question, I have a job where I have run MC through the walls and also have to feed a PVC floor outlet, in the past I have stubbed the PVC pipe up into a wall cavity between studs stripped the jacket off the MC used an approved connector and a PVC female adaptor On my most recent job the
MC Cable vs EMT — running in steel beam - Electrician Talk Hey all! First post here, have been learning a lot though the last few years I know there's a lot of discussion on MC Cable vs EMT However, I'm looking for opinions regarding wiring my own unfinished 600sf basement For reference, the basement is 30'x20' with a steel I-beam running down the
how to groud mc in a plastic box - Electrician Talk Ok, I'm looking for a way to ground mc cable sheathing in a plastic box Code allows metal conduit to enter a plastic box, however the crux of the matter
mc to emt - Electrician Talk connector ,rigid coupling,threaded mc connector, anti short, skin the mc long enough to go through conduit to first j-box or to point of termination
0-10V control - Electrician Talk If you run say, MC luminary cable in the conduit, this would satisfy, however problem is the cable termination I presume must be conduit? Could run two conduits? Or use a 'system' where the controller power pack does the dimming and you do not need the dimming wires in the switch box? There is also Digital (DLM) where you only need cat6 to the switch Remember this is all eng wet dream that