companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

MEGGER LIMITED

SCARBOROUGH-Canada

Company Name:
Corporate Name:
MEGGER LIMITED
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 110 Milner Ave,SCARBOROUGH,ON,Canada 
ZIP Code:
Postal Code:
M1S 
Telephone Number: 4162986770 
Fax Number:  
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
0 
USA SIC Description:
Cash Registers & Supplies (Who 
Number of Employees:
 
Sales Amount:
$2.5 to 5 million 
Credit History:
Credit Report:
Very Good 
Contact Person:
 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
MEGNA FURNITURE
MEGNA FURNITURE INC
MEGNA COLLECTION INC
Next company profile:
MEGASTRONG ENGINEERING & CONSTRUCTION
MEGAFUN 4 KIDS
MEGAFLEX FIRE PROTECTION










Company News:
  • Megging a 3 phase 480 volt motor - Electrician Talk
    What should the ohms be going from ground to phase on a digital megger? For a good motor should it read around what (400megaohms)? When the motor is bad it should read 0 ohms to ground? Need help clarifying this
  • Megger residential wiring - Electrician Talk
    A megger is simply a "megohm meter" and it only measures insulation resistance, at higher values than a regular ohm meter Generally a regular DMM operates at 9VDC on the ohm scale A megger will have selectable outputs of 50, 100, 250, 500, or 1000VDC to test insulation to ground or phase to phase as desired, at the proper voltage for the circuit under test It will not pin point the spot of
  • Megger - Electrician Talk
    Megger readings that do not stabilize, but fluctuate are indicative of moisture in or on the conductors and should be investigated Sometimes this reading will continue to climb as the moisture evaporates due to the test voltage When meggering one must be careful with the voltage levels you are trying to prevent future electrical damage to
  • megging a motor wired up - Electrician Talk
    A megger is used to test the integrity of insulation If you are testing a motor circuit wired to a MCC bucket or a VFD; Open the breaker in the bucket or isolated the VFD Always test your Megger first with leads together and leads apart Clamp onto the equipment ground with one lead and one of the T-leads with the other
  • Hi-Pot Vs Megger Testing - Electrician Talk
    I've never seen anyone hipot 600V cables A megger is a megohmeter, measures insulation resistance A hipot tester basically works the same way, but measures leakage current If you see a fault with the megger, you will see a fault with the hipot The hipot stresses the insulation weak points at higher voltage levels than the megger will I don't think the hi pot will do anything for you
  • What are expected Megger readings? - Electrician Talk
    You can damage this equipment or at a minimum get false readings Typically start with the lowest voltage your megger has, starting at 50, 100 or 250 VDC will minimize any chance of damaging equipment For trouble shooting single phase, I would megger Line to ground, line too neutral, neutral to ground
  • Motor Megs out Bad, Then Runs? - Electrician Talk
    It simply sums the three phase currents together (as a vector) and trips if the resulting calculated current exceeds around 10-20% of the average This is a much higher current than the micro amps that it takes to get a bad megger reading Read the manual because there are lots of causes for unbalanced currents not just a bad motor or wiring
  • Standards for Megger Testing - Electrician Talk
    I have looked through a bunch of posts regarding megger testing and not seeing what I am looking for I am looking for a “standard” that says this XX MΩ reading is a “pass” and this XX MΩ reading is a “fail” I am sure it is an IEEE standard, but I do not know for sure I have a couple pages
  • User Manuals - BiddleMegger. com