companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

NEC COMPUTERS

VINEYARD HAVEN-USA

Company Name:
Corporate Name:
NEC COMPUTERS
Company Title: Freezone 
Company Description:  
Keywords to Search:  
Company Address: 43 Oak St,VINEYARD HAVEN,MA,USA 
ZIP Code:
Postal Code:
1718 
Telephone Number: 5088810969 (+1-508-881-0969) 
Fax Number:  
Website:
sunistudios. com 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
737101 
USA SIC Description:
Computer Services 
Number of Employees:
 
Sales Amount:
 
Credit History:
Credit Report:
 
Contact Person:
 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
SAM SHERMAN ASSOCIATES
COLDWELL BANKER LANDMARKS R E
SHERIFFS MEADOW FOUNDATION
Next company profile:
GREENWOOD ASSOCIATES
JOHN CASEY PAINTING
MENEMSHA BLUES OAK BLUFF










Company News:
  • NEC Requirements for Generators and Standby Power Systems
    Mike Holt Enterprises, Inc • www MikeHolt com • 888 NEC CODE (632 2633) 5 NEC Requirements for Generators and Standby Power Systems 445 18 Disconnecting Means Generators must have one or more disconnecting means that disconnects all power, except where: Figure 445–7 (1) The driving means for the generator can be readily shut down, and
  • Mike holt - Electrician Talk
    TheNEC also requires certain types of circuits in specific places in addition to the minimum requirements based on the VA per sq ft calculation A dwelling unit kitchen, dining room, breakfast room, pantry, or similar area must have at least two 20A, 120V small-appliance receptacle
  • Feeders and Branch Circuits in the same Conduit.
    Is there an NEC article that requires Branch circuits and feeders to be in different conduits? Specifically I'm wondering about two panel tubs that are nipple together and do I need a separate nipple for the feeders and for the branch circuits
  • Gas station wiring requirements | Electrician Talk
    NEC 2017 514 8 Underground Wiring ENHANCED CONTENT Fuel spilled in the vicinity of gasoline dispensers seeps into the ground and could migrate into underground electrical conduits
  • Understanding Table 220-55 - Electrician Talk
    The NEC does not define ranges, ovens or cooktops but based on manufacturers usage a range is a unit that has a cooktop and oven built together in one appliance An oven is just a single or double appliance for baking , roasting, etc A cooktop is just the burners without the oven
  • 80% rule? - Electrician Talk
    80% rule applies to continious loads such as motors, lighting or any load expected to be on 3 hours or more A breaker is rated for 100% of the noncontinious load which may include outlets or other small appliance
  • Inconsistent Confusing Conduit Fill Calculation.
    As I said, according to NEC tables 9-1 and 9-5 1 2" EMT is acceptable I don't believe this is acceptable in this case and I don't think a local inspector or any of my local electricians would think it is even if a logically correct argument can be made to show it is allowed under NEC This is exactly my point
  • Table 300. 5 interpretation - Electrician Talk
    For a given column of Table 300 5 ("minimum cover requirements") there is a potential overlap of the various rows The one that concerns me at present is Column 2 (IMC and RMC conduit) If it's buried in a trench below 2" of concrete or equivalent, but also goes under a parking area in a
  • Stapling Romex - Electrician Talk
    And what code ref did this inspector use to justify his action? Let me guess, none We have a good system, if it needs correcting, the inspector files a form with the state The state sends me a fix it ticket that tells me the NEC section that I violated I have 14 days to correct and send the form back signed
  • Subpanel Behind Door : 110. 26(A)(2) | Electrician Talk
    My interpretation of NEC is panel behind door-swing is a code violation Subpanel Behind Door : 110 26(A)(2)




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer