copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
Wavepro Seat Pedestal - Michigan Sportsman Forum The Wave Pro pedestal is built on a FOX shock which is one of the kings of off-road shock absorbers They'll likely last a lifetime and will be easily rebuilt if necessary After talking to the folks at Wave Pro, I have no doubt they would fully stand behind their product if there was ever an issue
Whats a pedestal? | Information by Electrical Professionals for . . . The utility company trenches to the pedestal, they lay their wires in the trench, up into the pedestal and then make up their terminations What's nice with this setup is that we can install the service as soon as the basement foundation is back filled That means that there is usually permanent power to the house when we get in to start our rough
Pedestal Service | Information by Electrical Professionals for . . . Re: Pedestal Service Q1) Since pedestal has main disconnect, is exterior panel at house considered SUB which requires isolation on EGC Nuetral and pedestal considered Main ? A1) The post says that a four wire wire feeder is being intalled The grounded conductor must be isolated from the neutral at the house in this case
Boat Seat Wave Dampening Pedestal - Michigan Sportsman Forum What is everyone running for pedestal upgrades to help with the ride? Looking for any suggestions recommendations ideas I did run across this Springfield Ez-Ride Wave Dampening, but can't find much in regards to reviews or anything on it at this point Simply the $250 300 price tag sounds a bit more appetizing than $600+ seat
Help me identify a mobile home pedestal | Information by Electrical . . . One obvious need is a pedestal that is between the service connection on the street (which is also a pedestal with the meter and main breaker) and the panel on the actual mobile home itself This pedestal is near the mobile home's panel, and contains no breakers, but just a connection point for the underground feed from the meter to a flex that
Electrical pedestal | Information by Electrical Professionals for . . . If pedestal would only have receptacle(s) in it - then worst case it is a structure supplied by a branch circuit Supply it with a service or a feeder and it should need a grounding electrode system - typically ground rod(s) is what it used
pedestal seat planer mast question | Michigan Sportsman Forum The pedestal is the Swivle-eze or Springfield type with the black plastic wedge locking tab setup My question is, will the pedestal be strong enough to hold the mast in place while using the planer boards? I realize the pedestal tube is designed for a mostly downward force of a person sitting, not for outward (side) forces
Lets see you wall pedestal mounts | Michigan Sportsman Forum Looking for something different for this years mount and want to go wall pedestal Thinking mckensie 8900 but want to see what others have and looks in this thread in this sub-forum in the entire site
Pedestal service grounding | Information by Electrical Professionals . . . Re: Pedestal service grounding I have a three wire triplex (Bare is the neutral)feeding the sub-panel The sub-panel (Main lug) is grounded with a ground rod From the sub-panel they are running a 4-wire two hots one neutral and a ground to the gate
pedestal combination meter and main | Information by Electrical . . . Re: pedestal combination meter and main Adding a breaker to the pedestal in no way changes the method of installation, or negatively affects safety It changes which codes you have to adhere to, but they're brothers Article 225 Part II clearly paints outside feeders supplying a structure under virtually identical requirements as 230 does