About RLA | HVAC-Talk: Heating, Air Refrigeration Discussion What mean RLA? I know that literally mean Rated Load Amperage, but my question is what really means Example: a compressor nameplate say RLA=16, but an ammeter say amperage values are 8 3, 8 3, 8 6 (is a three phase motor) when the unit is running, and pressure is fine, sight glass is full
rla lra | HVAC-Talk: Heating, Air Refrigeration Discussion whats the differance in these two? i know they are run load amps and load run amps but there is a big differance in the numbers my understanding is that rla is the amps being drawn while running but what is lra?
RTHDs oil loss Capacity Limited By Low. . . - HVAC-Talk 12 degree approach @ 40% RLA is a problem for me, either you have some really fouled evap tubes, extremely low flow or your refrigerant is saturated with oil, you say the machine has failed many times on loss of oil, have any idea how much oil has been added to the machine?
For a system carries receiver, no liquid found in the. . . I checked the both coil were clean, the fans are both running, the compressor amps (14 amps) is lower than RLA (17 amps) is any possible has a restriction in the system? thank you! PS: For a system carries receiver, no liquid found in the sight glass, is this normal or abnormal?
compressor black over current box tripping - HVAC-Talk I'm working on a Aaon water cooled self contained unit ac only 3 months old first ac season, theirs a black phase monitor box that keeps blinking 3 times red light, code says overloaded compressor, I checked the compressors amps are good Freon running pressures are good they keep kicking off
What is the normal temperature for a running condenser. . . The motor was new, so I initially ruled it out - I should have been suspect And yes, most fans will run fairly close to or at their RLA unless it's mild out Is the Religious Right to blame for Christianity's decline? They argued that, as the Religious Right became increasingly visible and militant, it became associated with Christianity itself
Sizing Hard Start | HVAC-Talk: Heating, Air Refrigeration Discussion Volts 230 Phase 1 HZ 60 Compressor RLA 18 9 18 9 Compressor LRA 100 100 Fan FLA 1 3 Circuit Ampacity 25 25 Design PSI High 300 PSIG Design PSI Low 150 PSIG Factory Charge 94 OZ R22 The kits at my local supply are supco eclass and i need to determine the compressor HP to get the correct kit The above information is thats left on