What is difference between BTU and MBH for house furnaces? MBH is thousands of BTUs per hour BTU is a unit of measurement for energy One BTU is equal to the amount of energy used to raise the temperature of one pound of water one degree Fahrenheit The comments provided your answer, but no one posted the actual answer for you to accept
What size oven range based on new gas lines permitted BTUs? The plumber ran the line into the cabinet near the future gas range oven and ended it with an analog gauge Sorry for the delay I responded days ago but it didn't take for some reason
HVAC cooling latent capacity versus pints per hour It looks like the latent heat of a pint of water is about 1000 btu So if the sizing tool is saying I need 3,900 btu hr of latent capacity, and the spec sheet says the system can remove 7 pints hour, then I'm good to go, right ?
How do I estimate BTU usage to properly size new gas line? At minimum you should size for the single highest BTU appliance Pragmatically you can size for realistic or anticipated usage To be absolutely proper and ensure you have enough gas regardless of situation then size it for maximum BTU of all appliances Regardless of which previous option you choose just make sure to add 1 4 inch for good measure so that you can comfortably add a future
How to Interpret Calculate HVAC Load Impact from Rerigerators I am comparing options to purchase a single walk-in cooler, or several reach-in refrigerators to achieve similar storage capacity to the walk-in In addition to capital maintenance cost, redundancy
Is it worth it to insulate hot water PEX tubing? Is it worth the time and expense to put the foam pipe wrap on pex hot water pipes? I've seen mixed statements What is your thought? But more importantly, can you back it up?
Air conditioning with exhaust fans between two rooms Rule of thumb- and this is only an estimate - is 400 sq ft \ 3 5 kW (1 ton refrigeration = 12000 btuh = 3 5 kW) It could be 600, but you would need to know construction type, insulation, fenestration, exposure, latitude, etc and consult ACCA manual J With high humidity, you want to make sure it runs long enough to dehumidify
How can I connect a portable propane bottle to a tankless hot water . . . I actually have this setup, except I have teed two 40lb tanks together A comment above mentioned wetter space, and that is indeed the issue I have a high BTU regulator, but the tanks simply cannot evaporate enough propane to power the water heater at full blast (157,000 BTU) It's working "fine", not the end of the world, but occasionally when the washer is filling and we are using hot water