Minimum Required Size of Non-ADA Toilet Stall Where the combined total water closet compartments and urinals provided in a toilet room or bathing room is six or more, at least one ambulatory-accessible water closet compartment shall be provided in addition to the wheelchair-accessible compartment 1109 2 3 Lavatories
Non-ADA Toilet Stall Dimensions - The Building Code Forum A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction, or closer than 30 inches (762 mm) center to center between adjacent fixtures
Toilet sink overlap | The Building Code Forum The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space
A117. 1 Type B water closet clearances - The Building Code Forum 2009 A117 1 Type B Unit Water Closet Clearances Listed below are the clearance requirements for water closets Are hooks, toilet paper dispensers, grab bars allowed inside the required water closet clearance? The sections for Type B units do not allow them like the sections for Type A
Ambulatory restroom stall(s) - The Building Code Forum Where the combined total water closet compartments and urinals provided in a toilet room or bathing room is six or more, at least one ambulatory accessible water closet compartment shall be provided in addition to the wheelchair-accessible compartment
Water Closet Serves As Cleanout - The Building Code Forum Pun not intended! 2015 Section P3005 2 3 the cleanout for the building drain sewer junction; "For the requirements of this section, removal of a water closet shall not be required to provide cleanout access " Does that mean the water closet shall not serve as the cleanout for this section?
Water closet fixture drain | The Building Code Forum Knowledge check (mine): What is the minimum size of a water closet fixture drain in the IPC? Please include code reference Not a loaded question, I am trying to validate what I thought I knew but am finding difficult to find
Sink Center Line | The Building Code Forum Was wondering if the UPC had an equivalent section to the IPC regarding the required center line distance of a sink to the wall: 405 3 1 Water closets, urinals, lavatories and bidets A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to
Where do I find toilet clearances in California codes? In the city of LA, their standard correction list for single family residential says: H-13 Provide 15" minimum between the center of water closet to any side wall (Calif Plumb Code 407 6) H-14 Provide 24" clear space in front of any water closet (Calif Plumb Code 407 6) When I look at
Projections into clear floor space allowed, or not? water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space